DIN 70121 + OCPP 1.6J remote-start flow

One app-started DC session on a CCS2 charger, from driver tap to wallet debit. The vehicle and charger are each split in two: the EV's BMS (battery management) and its EVCC, and the charger's SECC and its power stage. DIN 70121 supports only ExternalPayment, has no TLS and no smart-charging schedules, and covers DC only. Pick any message to see its fields and timeout.

Order
AuthorizeRemoteTxRequests
Stop by
Request Response Electrical signal Internal action [6]Message code

DIN 70121 message codes

#Message#Message
1supportedAppProtocol7CableCheck
2SessionSetup8PreCharge
3ServiceDiscovery9PowerDelivery
4ServicePaymentSelection10CurrentDemand
5ContractAuthentication11WeldingDetection
6ChargeParameterDiscovery12SessionStop

Each request and its matching response use the same number.

Failure paths to handle

  • RemoteStartTransaction Rejected because the connector is Faulted, Unavailable or occupied.
  • No plug within ConnectionTimeOut: the charger returns to Available and sends no StartTransaction.
  • SLAC or SDP fails, or the car offers no matching protocol: no HLC session. Report it with a StatusNotification errorCode or vendor code.
  • Isolation fault in CableCheck (EVSEIsolationStatus = 3): the session aborts before any energy flows.
  • PreCharge never reaches the target within its time limit: the EV ends the session.
  • The WebSocket drops: Start/Stop/MeterValues are queued and sent in order once the charger reconnects.